Square d pumptrol pressure switch is intended to monitor and control electrically driven jet pumps submersible pumps or reciprocating pumps.
Square d well pump pressure switch adjustment.
Square d pumptrol pressure switches are commonly found in many commercial and residential plumbing applications that require the regulation of water pressure.
And will kill power to your pump when the water pressure reaches 60 lbs.
If the pump is starting and stopping at too low a pressure turn the larger nut clockwise.
Example pump pressure switch adjustment instructions from square d pressure control.
Square d pressure switch.
Prior to adjusting the switch follow safety precautions and look for any faults in the switch components.
The large nut adjustment is the easiest adjustment to make on the switch.
Under a normally set pressure switch the pump should come on at 30 psi and shut off at 50 psi.
A pressure switch is the mechanism that will turn on and turn off the well pump based on the pressure in the water system.
Square d 20 40 psi pumptrol water pressure switch on amazon https amzn to 2qw8rtv square d 30 50 psi pumptrol water pressure switch on amazon https a.
Click on the hyperlinks below to see pressure switch videos on the rc worst youtube channel.
Adjusting the square d well pressure switch increases the water pressure through the entire house.
The pumptrol fsg2j20bp electromechanical pressure switch by square d is the most trusted brand in residential commercial and industrial pumping applications.
The fsg2j20bp has a 20 psi to 40 psi pressure setting range activates an electrically driven water pump within a power circuit when the adjustable rising and falling thresholds are reached.
Adjust just a little at a time and allow the pump to operate.
Square d 30 50 psi pumptrol well pump water pressure switch clear packaging fsg2j21cp the home depot.
Turn the differential nut counterclockwise to lower cut off pressure or turn the nut clockwise to raise cut off pressure.
Adjust a square d well pressure switch by turning it clockwise to raise the pressure and counter clockwise to decrease the pressure.
On a square d pumptrol 9013fsf 2 pump pressure switch for example square d tells us that we.
Although pumptrol pressure switches are generally reliable sometimes problems can develop with the switch or with the associated water system.